Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2024-04 145,261 0.0% (0) 0.9% (1,354) 24.6% (35,733) 74.4% (108,011) 0.1% (163) 0.0% (0) 0.0% (0)
2024-03 164,781 0.0% (1) 1.0% (1,687) 20.4% (33,682) 74.6% (122,911) 0.3% (513) 0.0% (0) 3.6% (5,987)
2024-02 249,205 0.0% (0) 1.2% (2,964) 33.3% (83,040) 65.3% (162,824) 0.2% (377) 0.0% (0) 0.0% (0)
2024-01 248,955 0.0% (1) 1.0% (2,457) 29.6% (73,758) 68.7% (170,982) 0.6% (1,501) 0.0% (0) 0.1% (256)
2023
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2023-12 235,958 0.0% (1) 1.8% (4,218) 29.9% (70,637) 67.9% (160,273) 0.4% (829) 0.0% (0) 0.0% (0)
2023-11 243,236 0.0% (0) 0.7% (1,629) 37.7% (91,660) 61.6% (149,777) 0.1% (170) 0.0% (0) 0.0% (0)
2023-10 219,833 0.0% (0) 0.8% (1,698) 43.3% (95,265) 55.8% (122,702) 0.1% (168) 0.0% (0) 0.0% (0)
2023-09 245,694 0.0% (0) 0.5% (1,261) 59.4% (146,018) 40.1% (98,409) 0.0% (6) 0.0% (0) 0.0% (0)
2023-08 261,264 0.0% (0) 0.5% (1,258) 47.1% (123,064) 52.4% (136,942) 0.0% (0) 0.0% (0) 0.0% (0)
2023-07 247,408 0.0% (0) 0.3% (825) 62.8% (155,368) 36.9% (91,215) 0.0% (0) 0.0% (0) 0.0% (0)
2023-06 236,442 0.0% (0) 0.3% (821) 50.8% (120,121) 48.8% (115,495) 0.0% (5) 0.0% (0) 0.0% (0)
2023-05 225,080 0.0% (0) 0.7% (1,537) 26.6% (59,977) 72.7% (163,566) 0.0% (0) 0.0% (0) 0.0% (0)
2023-04 257,499 0.0% (0) 0.5% (1,339) 33.8% (86,970) 65.7% (169,190) 0.0% (0) 0.0% (0) 0.0% (0)
2023-03 266,962 0.0% (0) 0.6% (1,551) 33.0% (87,996) 66.5% (177,409) 0.0% (6) 0.0% (0) 0.0% (0)
2023-02 233,289 0.0% (0) 0.6% (1,447) 33.6% (78,342) 65.8% (153,500) 0.0% (0) 0.0% (0) 0.0% (0)
2023-01 224,185 0.0% (0) 0.3% (718) 48.6% (109,064) 51.0% (114,403) 0.0% (0) 0.0% (0) 0.0% (0)
2022
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2022-12 161,541 0.0% (0) 0.7% (1,103) 27.8% (44,889) 71.5% (115,539) 0.0% (10) 0.0% (0) 0.0% (0)
2022-11 241,986 0.0% (0) 0.5% (1,201) 25.7% (62,196) 73.8% (178,589) 0.0% (0) 0.0% (0) 0.0% (0)
2022-10 254,894 0.0% (0) 0.4% (981) 45.7% (116,507) 53.9% (137,406) 0.0% (0) 0.0% (0) 0.0% (0)
2022-09 254,172 0.0% (0) 0.5% (1,150) 41.6% (105,776) 57.9% (147,246) 0.0% (0) 0.0% (0) 0.0% (0)
2022-08 262,148 0.0% (0) 0.4% (1,137) 56.9% (149,171) 42.7% (111,840) 0.0% (0) 0.0% (0) 0.0% (0)
2022-07 267,100 0.0% (0) 0.7% (1,985) 30.6% (81,753) 68.6% (183,362) 0.0% (0) 0.0% (0) 0.0% (0)
2022-06 255,240 0.0% (0) 0.7% (1,762) 52.8% (134,754) 46.5% (118,724) 0.0% (0) 0.0% (0) 0.0% (0)
2022-05 265,309 0.0% (0) 0.4% (1,179) 44.0% (116,798) 55.5% (147,326) 0.0% (6) 0.0% (0) 0.0% (0)
2022-04 258,040 0.0% (0) 0.5% (1,350) 31.6% (81,413) 67.9% (175,277) 0.0% (0) 0.0% (0) 0.0% (0)
2022-03 267,411 0.0% (0) 0.5% (1,256) 34.3% (91,621) 65.3% (174,534) 0.0% (0) 0.0% (0) 0.0% (0)
2022-02 190,829 0.0% (0) 1.0% (1,935) 25.4% (48,434) 73.6% (140,460) 0.0% (0) 0.0% (0) 0.0% (0)
2022-01 243,364 0.0% (0) 0.7% (1,819) 33.9% (82,390) 65.4% (159,155) 0.0% (0) 0.0% (0) 0.0% (0)
2021
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2021-10 43 0.0% (0) 25.6% (11) 4.7% (2) 11.6% (5) 25.6% (11) 0.0% (0) 32.6% (14)
2021-04 2 100.0% (2) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)

Fault Frequency

This table shows the percentages and occurances of faults. A fault is when the inverter is in fault mode (system state is 11).

N Occurances Fault Code Fault Description
3,462 (92.0%)1250DC UNDER VOLT: The internal DC Boost voltage has dropped below its minimum threshold
233 (6.2%)7000GROUND FAULT: An input phase appears to be shorted to chassis ground
44 (1.2%)2280AC UNDER VOLT: The AC line voltage has dropped below its minimum threshold
26 (0.7%)8000AC OVER FREQ: The frequency of the utility grid voltage went out of range. The upper range threshold was crossed, or a ROCOF fault occurred.
3,765 total