Bergey Wind Power
James Provan's Bergey Excel
PowerSyncII Diagnostics
Username:
Password:
Remember Me

Turbine / Inverter Availability

2017
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2017-11 130,042 0.0% (0) 0.1% (109) 12.0% (15,614) 87.9% (114,297) 0.0% (22) 0.0% (0) 0.0% (0)
2017-10 154,619 0.0% (0) 1.3% (2,012) 9.2% (14,275) 89.1% (137,693) 0.4% (638) 0.0% (1) 0.0% (0)
2017-09 203,571 0.0% (0) 0.0% (69) 18.7% (38,053) 81.3% (165,430) 0.0% (19) 0.0% (0) 0.0% (0)
2017-08 231,692 0.0% (0) 0.0% (83) 15.8% (36,720) 84.1% (194,865) 0.0% (24) 0.0% (0) 0.0% (0)
2017-07 248,236 0.0% (0) 0.0% (53) 15.9% (39,564) 84.0% (208,603) 0.0% (16) 0.0% (0) 0.0% (0)
2017-06 245,509 0.0% (0) 0.0% (81) 13.2% (32,439) 86.7% (212,965) 0.0% (24) 0.0% (0) 0.0% (0)
2017-05 207,825 0.0% (0) 0.0% (35) 16.3% (33,912) 83.7% (173,871) 0.0% (7) 0.0% (0) 0.0% (0)
2017-04 245,176 0.0% (0) 0.0% (66) 8.1% (19,798) 91.9% (225,301) 0.0% (11) 0.0% (0) 0.0% (0)
2017-03 223,467 0.0% (0) 0.0% (54) 16.0% (35,687) 84.0% (187,719) 0.0% (7) 0.0% (0) 0.0% (0)
2017-02 207,521 0.0% (0) 0.0% (47) 0.0% (3) 100.0% (207,458) 0.0% (13) 0.0% (0) 0.0% (0)
2017-01 196,705 0.0% (0) 0.0% (43) 24.9% (49,044) 75.0% (147,603) 0.0% (15) 0.0% (0) 0.0% (0)
2016
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2016-12 252,401 0.0% (0) 0.1% (133) 24.4% (61,569) 75.5% (190,645) 0.0% (54) 0.0% (0) 0.0% (0)
2016-11 248,926 0.0% (0) 0.0% (89) 27.9% (69,415) 72.1% (179,392) 0.0% (30) 0.0% (0) 0.0% (0)
2016-10 257,758 0.0% (0) 0.0% (124) 27.8% (71,705) 72.1% (185,891) 0.0% (38) 0.0% (0) 0.0% (0)
2016-09 250,209 0.0% (0) 0.0% (36) 26.3% (65,921) 73.6% (184,240) 0.0% (12) 0.0% (0) 0.0% (0)
2016-08 240,527 0.0% (0) 0.0% (36) 27.8% (66,799) 72.2% (173,681) 0.0% (11) 0.0% (0) 0.0% (0)
2016-07 209,647 0.0% (0) 0.1% (164) 20.0% (41,981) 79.9% (167,442) 0.0% (60) 0.0% (0) 0.0% (0)
2016-06 167,862 0.0% (0) 0.1% (84) 36.4% (61,140) 63.5% (106,614) 0.0% (24) 0.0% (0) 0.0% (0)
2016-05 176,229 0.0% (0) 0.0% (10) 20.8% (36,575) 79.2% (139,640) 0.0% (4) 0.0% (0) 0.0% (0)
2016-04 167,962 0.0% (0) 0.0% (77) 16.9% (28,380) 83.0% (139,475) 0.0% (30) 0.0% (0) 0.0% (0)
2016-03 168,331 0.0% (0) 0.0% (34) 24.5% (41,299) 75.4% (126,992) 0.0% (6) 0.0% (0) 0.0% (0)
2016-02 169,514 0.0% (0) 0.1% (99) 16.9% (28,677) 83.0% (140,706) 0.0% (32) 0.0% (0) 0.0% (0)
2016-01 226,894 0.0% (0) 0.0% (27) 28.9% (65,625) 71.1% (161,236) 0.0% (6) 0.0% (0) 0.0% (0)
2015
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2015-12 191,346 0.0% (0) 0.1% (269) 14.5% (27,739) 85.3% (163,250) 0.0% (88) 0.0% (0) 0.0% (0)
2015-11 211,619 0.0% (0) 0.0% (103) 19.4% (41,022) 80.6% (170,461) 0.0% (33) 0.0% (0) 0.0% (0)
2015-10 230,728 0.0% (0) 0.0% (100) 35.1% (80,989) 64.8% (149,606) 0.0% (33) 0.0% (0) 0.0% (0)
2015-09 234,248 0.0% (0) 0.0% (17) 32.2% (75,474) 67.8% (158,753) 0.0% (4) 0.0% (0) 0.0% (0)
2015-08 252,669 0.0% (0) 0.0% (15) 22.6% (57,081) 77.4% (195,568) 0.0% (5) 0.0% (0) 0.0% (0)
2015-07 254,206 0.0% (0) 0.0% (127) 23.3% (59,235) 76.6% (194,802) 0.0% (42) 0.0% (0) 0.0% (0)
2015-06 245,727 0.0% (0) 0.0% (71) 27.2% (66,881) 72.7% (178,757) 0.0% (18) 0.0% (0) 0.0% (0)
2015-05 211,891 0.0% (0) 0.1% (142) 9.8% (20,834) 90.1% (190,863) 0.0% (52) 0.0% (0) 0.0% (0)
2015-04 208,723 0.0% (0) 0.0% (71) 24.8% (51,688) 75.2% (156,940) 0.0% (24) 0.0% (0) 0.0% (0)
2015-03 225,015 0.0% (0) 0.0% (101) 17.6% (39,519) 82.4% (185,359) 0.0% (36) 0.0% (0) 0.0% (0)
2015-02 228,448 0.0% (0) 0.0% (56) 9.9% (22,503) 90.1% (205,871) 0.0% (18) 0.0% (0) 0.0% (0)
2015-01 257,009 0.0% (0) 0.1% (277) 13.3% (34,210) 86.5% (222,426) 0.0% (96) 0.0% (0) 0.0% (0)
2014
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2014-12 189,947 0.0% (0) 0.1% (114) 10.5% (19,954) 89.4% (169,837) 0.0% (42) 0.0% (0) 0.0% (0)
2014-11 178,037 0.0% (0) 0.0% (19) 31.1% (55,358) 68.9% (122,653) 0.0% (7) 0.0% (0) 0.0% (0)
2014-10 233,991 0.0% (0) 0.0% (0) 15.8% (37,024) 84.2% (196,967) 0.0% (0) 0.0% (0) 0.0% (0)
2014-09 139,592 0.0% (0) 0.0% (54) 52.4% (73,132) 47.6% (66,388) 0.0% (18) 0.0% (0) 0.0% (0)
2014-08 199,633 0.0% (0) 0.1% (110) 20.9% (41,658) 79.1% (157,829) 0.0% (36) 0.0% (0) 0.0% (0)
2014-07 180,062 0.0% (0) 0.0% (55) 33.6% (60,476) 66.4% (119,513) 0.0% (18) 0.0% (0) 0.0% (0)
2014-06 162,613 0.0% (0) 0.0% (0) 35.2% (57,299) 64.8% (105,314) 0.0% (0) 0.0% (0) 0.0% (0)
2014-05 122,534 0.0% (0) 0.0% (36) 13.1% (15,991) 86.9% (106,494) 0.0% (13) 0.0% (0) 0.0% (0)
2014-04 170,365 0.0% (0) 0.0% (18) 16.5% (28,058) 83.5% (142,283) 0.0% (6) 0.0% (0) 0.0% (0)
2014-03 178,090 0.0% (0) 0.1% (90) 7.7% (13,728) 92.2% (164,247) 0.0% (24) 0.0% (1) 0.0% (0)
2014-02 132,659 0.0% (0) 0.0% (37) 9.9% (13,116) 90.1% (119,494) 0.0% (12) 0.0% (0) 0.0% (0)
2014-01 135,097 0.0% (0) 0.0% (30) 17.5% (23,605) 82.5% (111,450) 0.0% (12) 0.0% (0) 0.0% (0)
2013
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2013-12 120,722 0.0% (0) 0.1% (168) 5.5% (6,669) 94.3% (113,830) 0.0% (55) 0.0% (0) 0.0% (0)
2013-11 154,601 0.0% (0) 0.0% (54) 19.3% (29,915) 80.6% (124,614) 0.0% (18) 0.0% (0) 0.0% (0)
2013-10 163,428 0.0% (0) 0.0% (45) 11.7% (19,184) 88.2% (144,189) 0.0% (10) 0.0% (0) 0.0% (0)
2013-09 174,429 0.0% (0) 0.0% (11) 21.2% (36,986) 78.8% (137,432) 0.0% (0) 0.0% (0) 0.0% (0)
2013-08 180,325 0.0% (0) 0.0% (54) 26.8% (48,292) 73.2% (131,966) 0.0% (13) 0.0% (0) 0.0% (0)
2013-07 189,382 0.0% (0) 0.1% (104) 23.6% (44,612) 76.4% (144,624) 0.0% (42) 0.0% (0) 0.0% (0)
2013-06 128,973 0.0% (0) 0.1% (72) 21.7% (28,004) 78.2% (100,878) 0.0% (19) 0.0% (0) 0.0% (0)
2013-05 138,256 0.0% (0) 0.1% (182) 10.4% (14,444) 89.4% (123,562) 0.0% (68) 0.0% (0) 0.0% (0)
2013-04 197,975 0.0% (0) 0.1% (156) 8.6% (17,043) 91.3% (180,721) 0.0% (55) 0.0% (0) 0.0% (0)
2013-03 135,900 0.0% (0) 0.1% (164) 11.1% (15,150) 88.7% (120,536) 0.0% (50) 0.0% (0) 0.0% (0)

Fault Frequency

This table shows the percentages and occurances of faults. A fault is when the inverter is in fault mode (system state is 11).

N Occurances Fault Code Fault Description
1,064 (89.3%)8000AC OVER FREQ: The frequency of the utility grid voltage went out of range. The upper range threshold was crossed, or a ROCOF fault occurred.
83 (7.0%)2280AC UNDER VOLT: The AC line voltage has dropped below its minimum threshold
23 (1.9%)1000DC OVER VOLT 1: The DC Bus voltage has exceeded its maximum threshold
21 (1.8%)2030AC OVER VOLT: The AC line voltage has exceeded its maximum threshold
1,191 total