Bergey Wind Power
Richton Park Community Center Bergey Excel
PowerSyncII Diagnostics
Username:
Password:
Remember Me

Turbine / Inverter Availability

2025
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2025-09 1,555 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (1,555) 0.0% (0) 0.0% (0)
2025-08 90,004 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (90,004) 0.0% (0) 0.0% (0)
2025-07 63,576 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (63,576) 0.0% (0) 0.0% (0)
2025-06 75,985 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (75,985) 0.0% (0) 0.0% (0)
2025-05 56,952 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (56,952) 0.0% (0) 0.0% (0)
2025-04 70,468 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (70,468) 0.0% (0) 0.0% (0)
2025-03 64,792 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (64,792) 0.0% (0) 0.0% (0)
2025-02 46,884 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (46,884) 0.0% (0) 0.0% (0)
2025-01 149,459 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (149,459) 0.0% (0) 0.0% (0)
2024
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2024-12 78,969 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (78,969) 0.0% (0) 0.0% (0)
2024-11 76,448 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (76,448) 0.0% (0) 0.0% (0)
2024-10 62,730 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (62,730) 0.0% (0) 0.0% (0)
2024-09 78,519 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (78,519) 0.0% (0) 0.0% (0)
2024-08 34,308 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (34,308) 0.0% (0) 0.0% (0)
2024-07 58,848 0.0% (0) 0.0% (6) 4.2% (2,500) 1.3% (740) 94.5% (55,602) 0.0% (0) 0.0% (0)
2024-06 100,410 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (100,410) 0.0% (0) 0.0% (0)
2024-05 109,076 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (109,076) 0.0% (0) 0.0% (0)
2024-04 135,047 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (135,047) 0.0% (0) 0.0% (0)
2024-03 84,002 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (84,002) 0.0% (0) 0.0% (0)
2024-02 94,992 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (94,992) 0.0% (0) 0.0% (0)
2024-01 108,287 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (108,287) 0.0% (0) 0.0% (0)
2023
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2023-12 93,131 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (93,131) 0.0% (0) 0.0% (0)
2023-11 141,637 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (141,637) 0.0% (0) 0.0% (0)
2023-10 181,114 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (181,114) 0.0% (0) 0.0% (0)
2023-09 185,886 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (185,886) 0.0% (0) 0.0% (0)
2023-08 141,956 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (141,956) 0.0% (0) 0.0% (0)
2023-07 80,628 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (80,628) 0.0% (0) 0.0% (0)
2023-06 96,190 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (96,190) 0.0% (0) 0.0% (0)
2023-05 186,105 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (186,105) 0.0% (0) 0.0% (0)
2023-04 173,707 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (173,707) 0.0% (0) 0.0% (0)
2023-03 14,685 0.0% (0) 0.1% (18) 2.1% (315) 97.7% (14,352) 0.0% (0) 0.0% (0) 0.0% (0)
2021
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2021-06 106,249 0.0% (0) 0.0% (42) 100.0% (106,202) 0.0% (0) 0.0% (5) 0.0% (0) 0.0% (0)
2021-05 45,184 0.0% (0) 0.0% (0) 100.0% (45,184) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2021-04 81,949 0.0% (0) 0.0% (0) 100.0% (81,949) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2021-03 76,794 0.0% (0) 0.0% (26) 99.7% (76,561) 0.0% (0) 0.3% (207) 0.0% (0) 0.0% (0)
2021-02 175,833 0.0% (0) 0.0% (0) 100.0% (175,833) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2021-01 235,153 0.0% (0) 0.0% (0) 100.0% (235,153) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2020
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2020-12 209,686 0.0% (0) 0.0% (0) 100.0% (209,686) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2020-11 150,562 0.0% (0) 0.0% (15) 100.0% (150,547) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2020-10 172,939 0.0% (0) 0.0% (0) 100.0% (172,939) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2020-09 136,387 0.0% (0) 0.0% (15) 100.0% (136,371) 0.0% (0) 0.0% (1) 0.0% (0) 0.0% (0)
2020-08 107,873 0.0% (0) 0.0% (11) 100.0% (107,837) 0.0% (0) 0.0% (4) 0.0% (0) 0.0% (21)
2020-07 249,161 0.0% (0) 0.0% (33) 100.0% (249,124) 0.0% (0) 0.0% (4) 0.0% (0) 0.0% (0)
2020-06 247,607 0.0% (0) 0.0% (112) 100.0% (247,485) 0.0% (1) 0.0% (9) 0.0% (0) 0.0% (0)
2020-05 164,892 0.0% (0) 0.0% (0) 100.0% (164,892) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2020-04 181,507 0.0% (0) 0.0% (0) 100.0% (181,507) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2020-03 77,574 0.0% (0) 0.0% (0) 100.0% (77,574) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2020-02 188,716 0.0% (0) 0.0% (0) 100.0% (188,716) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2020-01 174,848 0.0% (0) 0.0% (0) 100.0% (174,848) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2019
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2019-12 180,828 0.0% (0) 0.0% (13) 100.0% (180,815) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2019-11 116,280 0.0% (0) 0.0% (0) 100.0% (116,280) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2019-10 196,315 0.0% (0) 0.0% (74) 100.0% (196,241) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)
2019-09 225,657 0.0% (0) 0.0% (10) 0.3% (648) 0.0% (0) 99.7% (224,999) 0.0% (0) 0.0% (0)
2019-08 208,339 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (208,339) 0.0% (0) 0.0% (0)
2019-07 242,058 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (242,058) 0.0% (0) 0.0% (0)
2019-06 182,975 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (182,975) 0.0% (0) 0.0% (0)
2019-05 186,290 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (186,290) 0.0% (0) 0.0% (0)
2019-04 158,671 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (158,671) 0.0% (0) 0.0% (0)
2019-03 223,668 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (223,668) 0.0% (0) 0.0% (0)
2019-02 152,143 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (152,143) 0.0% (0) 0.0% (0)
2019-01 205,865 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (205,865) 0.0% (0) 0.0% (0)
2018
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2018-12 175,126 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (175,126) 0.0% (0) 0.0% (0)
2018-11 100,464 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (100,464) 0.0% (0) 0.0% (0)
2018-10 166,853 0.0% (0) 0.0% (8) 2.0% (3,348) 12.6% (20,977) 85.4% (142,520) 0.0% (0) 0.0% (0)
2018-09 182,112 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (182,112) 0.0% (0) 0.0% (0)
2018-08 106,362 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (106,362) 0.0% (0) 0.0% (0)
2018-07 115,051 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (115,051) 0.0% (0) 0.0% (0)
2018-06 165,989 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (165,989) 0.0% (0) 0.0% (0)
2018-05 150,404 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (150,404) 0.0% (0) 0.0% (0)
2018-04 206,431 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (206,431) 0.0% (0) 0.0% (0)
2018-03 215,370 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (215,370) 0.0% (0) 0.0% (0)
2018-02 149,056 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (149,056) 0.0% (0) 0.0% (0)
2018-01 176,268 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (176,268) 0.0% (0) 0.0% (0)
2017
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2017-12 150,341 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (150,341) 0.0% (0) 0.0% (0)
2017-11 166,026 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (166,026) 0.0% (0) 0.0% (0)
2017-10 170,038 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (170,038) 0.0% (0) 0.0% (0)
2017-09 102,882 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (102,882) 0.0% (0) 0.0% (0)
2017-08 135,641 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (135,641) 0.0% (0) 0.0% (0)
2017-07 151,759 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (151,759) 0.0% (0) 0.0% (0)
2017-06 150,294 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (150,294) 0.0% (0) 0.0% (0)
2017-05 173,772 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (173,772) 0.0% (0) 0.0% (0)
2017-04 180,490 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (180,490) 0.0% (0) 0.0% (0)
2017-03 191,672 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (191,672) 0.0% (0) 0.0% (0)
2017-02 205,832 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (205,832) 0.0% (0) 0.0% (0)
2017-01 246,783 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (246,783) 0.0% (0) 0.0% (0)
2016
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2016-12 227,559 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (227,559) 0.0% (0) 0.0% (0)
2016-11 183,734 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (183,734) 0.0% (0) 0.0% (0)
2016-10 179,262 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (179,262) 0.0% (0) 0.0% (0)
2016-09 168,371 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (168,371) 0.0% (0) 0.0% (0)
2016-08 247,926 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (247,926) 0.0% (0) 0.0% (0)
2016-07 236,143 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (236,143) 0.0% (0) 0.0% (0)
2016-06 220,213 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (220,213) 0.0% (0) 0.0% (0)
2016-05 243,945 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (243,945) 0.0% (0) 0.0% (0)
2016-04 196,235 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (196,235) 0.0% (0) 0.0% (0)
2016-03 198,495 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (198,495) 0.0% (0) 0.0% (0)
2016-02 189,648 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (189,648) 0.0% (0) 0.0% (0)
2016-01 156,557 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (156,557) 0.0% (0) 0.0% (0)
2015
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2015-12 155,791 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (155,791) 0.0% (0) 0.0% (0)
2015-11 217,924 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (217,924) 0.0% (0) 0.0% (0)
2015-10 148,440 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (148,440) 0.0% (0) 0.0% (0)
2015-09 122,519 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (122,519) 0.0% (0) 0.0% (0)
2015-08 110,324 0.0% (0) 0.0% (15) 1.4% (1,590) 82.1% (90,569) 16.5% (18,150) 0.0% (0) 0.0% (0)
2015-07 124,376 0.0% (0) 0.0% (15) 0.0% (0) 100.0% (124,359) 0.0% (2) 0.0% (0) 0.0% (0)
2015-06 100,501 0.0% (0) 0.0% (37) 0.0% (0) 100.0% (100,458) 0.0% (6) 0.0% (0) 0.0% (0)
2015-05 191,526 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (191,526) 0.0% (0) 0.0% (0) 0.0% (0)
2015-04 190,585 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (190,585) 0.0% (0) 0.0% (0) 0.0% (0)
2015-03 163,795 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (163,795) 0.0% (0) 0.0% (0) 0.0% (0)
2015-02 165,370 0.0% (0) 0.0% (57) 0.0% (0) 100.0% (165,306) 0.0% (7) 0.0% (0) 0.0% (0)
2015-01 109,107 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (109,107) 0.0% (0) 0.0% (0) 0.0% (0)
2014
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2014-12 139,350 0.0% (0) 0.0% (13) 0.0% (0) 100.0% (139,336) 0.0% (1) 0.0% (0) 0.0% (0)
2014-11 118,372 0.0% (0) 0.0% (29) 0.0% (0) 27.8% (32,887) 72.2% (85,455) 0.0% (1) 0.0% (0)
2014-10 144,687 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (144,687) 0.0% (0) 0.0% (0)
2014-09 105,928 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (105,928) 0.0% (0) 0.0% (0)
2014-08 150,952 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (150,952) 0.0% (0) 0.0% (0)
2014-07 196,333 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (196,333) 0.0% (0) 0.0% (0)
2014-06 194,806 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (194,806) 0.0% (0) 0.0% (0)
2014-05 194,765 0.0% (0) 0.0% (63) 7.1% (13,799) 65.2% (126,897) 27.7% (54,006) 0.0% (0) 0.0% (0)
2014-04 215,219 0.0% (0) 0.0% (0) 4.8% (10,224) 95.2% (204,995) 0.0% (0) 0.0% (0) 0.0% (0)
2014-03 163,386 0.0% (0) 0.0% (44) 9.4% (15,305) 90.6% (148,035) 0.0% (2) 0.0% (0) 0.0% (0)
2014-02 85,417 0.0% (0) 0.0% (0) 11.4% (9,749) 88.6% (75,668) 0.0% (0) 0.0% (0) 0.0% (0)
2014-01 116,103 0.0% (0) 0.0% (29) 2.5% (2,864) 97.5% (113,208) 0.0% (2) 0.0% (0) 0.0% (0)
2013
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2013-12 122,426 0.0% (0) 0.0% (31) 11.9% (14,563) 88.1% (107,830) 0.0% (2) 0.0% (0) 0.0% (0)
2013-11 100,606 0.0% (0) 0.0% (0) 5.9% (5,955) 94.1% (94,651) 0.0% (0) 0.0% (0) 0.0% (0)
2013-10 116,696 0.0% (0) 0.0% (13) 9.9% (11,610) 90.0% (105,071) 0.0% (2) 0.0% (0) 0.0% (0)
2013-09 96,154 0.0% (0) 0.1% (59) 10.5% (10,128) 89.4% (85,964) 0.0% (3) 0.0% (0) 0.0% (0)
2013-08 114,589 0.0% (0) 0.1% (67) 23.2% (26,594) 76.7% (87,922) 0.0% (6) 0.0% (0) 0.0% (0)
2013-07 210,990 0.0% (0) 1.0% (2,060) 14.5% (30,678) 84.5% (178,234) 0.0% (18) 0.0% (0) 0.0% (0)
2013-06 246,059 0.0% (0) 0.1% (230) 15.0% (36,903) 84.9% (208,914) 0.0% (12) 0.0% (0) 0.0% (0)
2013-05 237,151 0.0% (0) 0.0% (32) 11.2% (26,498) 88.8% (210,618) 0.0% (3) 0.0% (0) 0.0% (0)
2013-04 175,905 0.0% (0) 0.0% (35) 6.4% (11,294) 93.6% (164,573) 0.0% (3) 0.0% (0) 0.0% (0)
2013-03 161,196 0.0% (0) 0.0% (0) 11.4% (18,438) 88.6% (142,758) 0.0% (0) 0.0% (0) 0.0% (0)
2013-02 167,804 0.0% (0) 0.0% (0) 8.9% (14,903) 91.1% (152,901) 0.0% (0) 0.0% (0) 0.0% (0)
2013-01 187,436 0.0% (0) 0.0% (0) 7.0% (13,194) 93.0% (174,242) 0.0% (0) 0.0% (0) 0.0% (0)
2012
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2012-12 75,724 0.0% (0) 0.0% (0) 6.3% (4,738) 93.7% (70,986) 0.0% (0) 0.0% (0) 0.0% (0)
2012-11 14,700 0.0% (0) 0.0% (0) 13.1% (1,922) 86.9% (12,778) 0.0% (0) 0.0% (0) 0.0% (0)
2012-03 38 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (38) 0.0% (0) 0.0% (0) 0.0% (0)
2012-02 1 0.0% (0) 0.0% (0) 0.0% (0) 100.0% (1) 0.0% (0) 0.0% (0) 0.0% (0)
2012-01 7,874 0.0% (0) 0.0% (0) 20.9% (1,642) 79.1% (6,232) 0.0% (0) 0.0% (0) 0.0% (0)
2011
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2011-12 4,603 0.0% (0) 0.3% (16) 14.6% (671) 85.1% (3,916) 0.0% (0) 0.0% (0) 0.0% (0)
2011-11 94,903 0.0% (0) 0.0% (20) 6.8% (6,409) 93.2% (88,473) 0.0% (1) 0.0% (0) 0.0% (0)
2011-10 41,117 0.0% (0) 0.0% (0) 8.7% (3,592) 91.3% (37,525) 0.0% (0) 0.0% (0) 0.0% (0)
2010
Month Total Reports Initialization Stopped Waiting for Wind Running Fault Manual Stop Fault Limit
2010-11 92 100.0% (92) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0) 0.0% (0)

Fault Frequency

This table shows the percentages and occurances of faults. A fault is when the inverter is in fault mode (system state is 11).

N Occurances Fault Code Fault Description
5,368,079 (100.0%)10INTERNAL ERROR: IGBT Desat or control logic fault. An occurrence of this fault requires that the unit be completely powered down to reset it.
207 (0.0%)1250DC UNDER VOLT: The internal DC Boost voltage has dropped below its minimum threshold
23 (0.0%)2280AC UNDER VOLT: The AC line voltage has dropped below its minimum threshold
5,368,309 total